With an eye toward its mission to protect people and the environment through the safe transportation of hazardous materials, the U.S. Department of Transportation’s pipeline safety bureau has issued an advisory bulletin on corrosion related to insulated coatings on buried pipelines.
The Pipeline and Hazardous Materials Safety Administration (PHMSA) uses advisory bulletins to inform pipeline operators and federal and state pipeline safety personnel of matters that have the potential of becoming safety or environmental risks.
Photos: PHMSA |
Prompted by the investigation into the failure of Plains Line 901, which was found to be the result of extensive external corrosion under the insulated coating, a federal pipeline safety group is advising pipeline owners, operators and other personnel to review their operating, maintenance and integrity management activities. |
The newest advisory bulletin, published in the Federal Register and announced Friday (June 24), urges pipeline owners and operators to review their operating, maintenance and integrity management activities to ensure that their insulated and buried pipelines have effective coating and corrosion control systems in place.
Teaching By Example
PHMSA released “Pipeline Safety: Ineffective Protection, Detection, and Mitigation of Corrosion Resulting From Insulated Coatings on Buried Pipelines” in response to the failure of Plains All American Pipeline LP Line 901 in Santa Barbara, CA.
The final investigation report into the Line 901 crude oil spill indicated that the buried pipeline failed due to extensive external corrosion that occurred under the insulated coating.
As a result, the PHMSA advisory advises operators to become familiar with the circumstances that contributed to the Line 901 accident (summarized in the advisory bulletin), as well as to consider the preventative and mitigative actions the advisory recommends for minimizing failures.
Procedural Recommendations
In addition to having effective cathodic protection (CP) systems in place, personnel are reminded to conduct in-line inspections for all threats and to ensure in-line inspection tool findings are accurate, verified and conducted for all pipeline threats.
PHMSA urges operators and other pipeline personnel to consider preventative and mitigative actions, as outlined in its advisory, to minimize failures, protect the environment and ensure the safety of the public. |
Specifically, PHMSA advises owners and personnel to consider procedures for insulated and buried pipelines that include: