August 22 - August 28, 2011
In your experience, what is the most common cause of premature coating failures?
More items for
Quality Control
| Answers |
Votes |
|
Poor workmanship
|
76% |
|
Incorrect specification
|
12% |
|
Unforeseen exposure condition (due to design defect, for instance)
|
10% |
|
Defective coating material
|
2% |
|
Suggest a topic
Tagged categories:
Coating failure
|
|
Comment from Glenn Summers, (8/25/2011, 6:36 AM)
|
Speaking only as it relates to concrete substrates; most specifications do not go far enough to insure that a concrete is properly treated, prior to the coating application. If a concrete is not "Stabilized" prior to coating, the Gel-Pore/Capillary system of the concrete will remain Open and Active to expell a concrete internal chemistry for years to come. Often, a specification is written to take in to account Harsh Service Environments as it relates to contaminates entering a concrete matrix from the exterior of a structure. It is one thing to attempt to protect a concrete by coating the exterior, but this type of specification falls short of a "Durable Surface". Great care and expense of sand blasting, high pressure washes and even acid etching will attempt to obtain longevity of a coating, but do not consider that an unstable concrete will allow moisture vapor to deposit chemicals underneath the best of coatings. When this internal chemistry and moisture migrates out to an atmosphere, coating failures are certain. A specification that doesn't address moisture travel In and Out of a concrete substrate will lead to a coating failure, not to mention all of the other deleterious events that occur to a concrete. When Carbonation is allowed to reduce the internal pH of a concrete below 11.5 pH, a coating loss is a minor problem compared to the corrosion cells that are now allowed to form on the reinforcing steel! At this point, "Another Coat of Paint Won't Help"!
|
|
|
Comment from Chuck Stevens, (8/31/2011, 12:18 PM)
|
It is extremely Important that the inspection attends the Pre-Job conference to discuss grey area's and how they should be addressed as agreed to by all involved
|
|
|
Join the Conversation:
|
|
Sign in to our community to add your comments.
|
|
|
|
|
|

High-precision coating thickness gauge MiniTest 7400
MiniTest 7400 with intuitive menu control, enhanced data management with configuration assistent. Wear-resistant sensors for measuring tasks up to 35mm thickness.

NEW PosiTector Inspection Kits
PosiTector 6000 Coating Thickness Gage easily converts to a surface profile gage, dew point meter or ultrasonic wall thickness gage with a simple probe change.

Gauges Meet IMO-PSPC & SSPC-PA2 Requirements
• USB or optional Bluetooth • Custom inspection reports • Excellent on edges & rough surfaces; Optimum accuracy • Largest selection of probes to meet challenging situations Call Fischer: 800-243-8417

Schmidt Introduces the New miniBRS
Reduced in size, it is incredibly easy to maneuver and operate! The perfect alternative to larger blast & recovery units when project space is limited. Call 1-800-231-2085

LS Blasters: Optimum Steel Cleaning Efficiency
Simplify surface prep with the
precise shot control of LS Blasters.
Our blast technology delivers
optimum coverage and finish. 800-533-8008
No Ordinary Soda
ARMEX® baking soda-based abrasives from the makers of ARM & HAMMER® products offers over 12 formulas specially engineered for your application and your budget.

http://www.sspc.org/